V2000-c Rfid Access Control User Manual !new! -

: Press * to exit and return to normal operation.

The Ultimate Setup & Troubleshooting Guide for the V2000-C RFID Access Control System

This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.

Press 0 + New Master Code + # + Confirm New Master Code + # . V2000-c Rfid Access Control User Manual

| Parameter | Specification | | :--- | :--- | | | V2000-C | | Operating Voltage | DC 12V ± 10% | | Unlock Relay / Current | 12VDC / 2A, < 1000mA | | Standby Current | < 60mA | | User Capacity | 1000 Standard Users (Cards or PINs) | | Supported Card Type | 125kHz EM Card (ID Card) | | Read Range | 5 - 15 cm (2 - 6 inches) | | PIN Code Length | 4-digit User Code; 6-digit PIN | | Operating Temperature | -10°C ~ 70°C (14°F ~ 158°F) | | Operating Humidity | 10% - 90% RH | | Dimensions | 117mm x 117mm x 21mm | | Weight | Varies by model |

Valid card read, valid PIN entry, or successful keystroke.

For more detailed technical specifications and troubleshooting, refer to official OboHands user manual downloads . : Press * to exit and return to normal operation

Connect the wire to the +12V output of your access control power supply.

Before installation, ensure your environment meets the following requirements: DC 12V ±10% User Capacity: 1,000 to 2,500 users (model dependent) Card Reading Distance: 3–6 cm Card Type: ID (EM) card or IC (Mifare) card Output Interface: Wiegand 26 (for external readers) Lock Output Load: Max 3A 2. Installation and Wiring

Cards can be assigned rapidly in succession or tied directly to individual slot indexes. If you share with third parties, their policies apply

The Green LED will turn solid or flash to indicate active programming mode. Step 2: Modifying the Default Admin Code

To program the device, you must enter Programming Mode. The default Master Programming Code is typically or 123456 . Entering and Exiting Programming Mode

| Error Symptom | Probable Cause | Solution | | :--- | :--- | :--- | | | Blown fuse on power supply or reverse polarity. | Check PSU, measure voltage at terminals 1 & 2 (must be 10-14V DC). | | Card beeps but lock doesn’t open | Lock wired to wrong relay (NO vs NC). | Swap lock wire from NO to COM or NC to COM. | | Lock opens for 1 second then closes | Insufficient power supply amperage (lock surge). | Upgrade to 12V DC 5A PSU. Add a capacitor across lock power. | | Continuous alarm after door closes | Door contact sensor (SEN) stuck or misaligned. | Check reed switch gap (<10mm). Set 16 0 # to disable temporarily. | | “Error” beep (two short beeps) | Command syntax error or user not found. | Re-enter command slowly. Use 14 to verify user exists. | | Master code not accepted | Someone changed it, or keypad is faulty. | Perform emergency reset (jumper method). | | RFID range is <1cm | Interference from metal or voltage drop. | Mount on non-metallic spacer. Check 12V at reader (terminal 2 & 10). |