While official municipal portals have undergone significant digital restructuring recently, many professionals are looking for accessible digital copies.
PR-402 classifies public areas into distinct categories based on traffic volume, speed, and pedestrian usage. Designers must achieve specific luminance ( ) or illuminance ( ) levels, along with strict uniformity ratios ( U0cap U sub 0
Uniformity Ratios: Ensuring there are no "dark spots" between light poles. pr 402 abu dhabi lighting manual free
Varies by road class; for example, Highways/Freeways require a luminance of 1.0 cd/m² (approx. 15–25 lux depending on the class).
The "PR" stands for "Procedure," and this document outlines every technical, electrical, and photometric requirement for external lighting across the Emirate of Abu Dhabi, including Al Ain and the Western Region. It supersedes older standards (like the 2006 versions) and aligns Abu Dhabi with international best practices (CIE, IESNA) while addressing local environmental and cultural needs. Varies by road class; for example, Highways/Freeways require
The PR-402 manual defines several technical parameters to ensure uniformity and safety across the city's infrastructure: Lighting Classes: Roadways are categorized into classes such as (major routes, ~20-25 lux) and (secondary routes, ~15 lux). Color Temperature (CCT): Roadway/Parking: Standard LED colors are 2700K, 3000K, and 4000K. Dark Sky Compliance:
Mandatory integration of Surge Protection Devices (SPDs) within LED luminaires to safeguard sensitive electronic drivers from voltage spikes caused by lightning or grid switching. It supersedes older standards (like the 2006 versions)
The PR 402 Abu Dhabi Lighting Manual is a valuable resource for anyone involved in lighting design, installation, and maintenance in Abu Dhabi. By providing guidelines and standards for lighting practices, the manual helps to ensure that lighting systems are safe, efficient, and aesthetically pleasing. As a free resource, it is widely accessible to architects, engineers, contractors, and building owners, promoting best practices and compliance with local regulations.
: Intersections, roundabouts, and pedestrian crossings demand higher illuminance metrics (measured in Lux) due to complex traffic movements.