Factorytalk View Se Version 13 Jun 2026

Are you currently troubleshooting a or planning a system upgrade from an older version? FactoryTalk View Site Edition Installation Guide

Detail the for a Version 13 server installation.

FactoryTalk View Site Edition Software - Rockwell Automation factorytalk view se version 13

As cyber threats in industrial environments continue to evolve, v13 strengthens security measures.

: A known "Data Server is not available" error in v13 is often resolved by ensuring the Windows user/password of the client matches those of the server's Windows login. Key Resources for Implementation Are you currently troubleshooting a or planning a

| Component | CPU | RAM | |-----------|-----|-----| | Operator Workstation | Intel Core i5 Standard Power processor | 4 GB | | Engineering Workstation | Intel Core i5 Standard Power processor | 8 GB | | Application Server (Smaller Systems) | Intel Core i5 Standard Power processor | 4 GB | | Application Server (Medium to Larger Systems) | Quad core Intel Xeon family processor | 8 GB |

In version 13, some users cannot access the "Connections" tab for OLE objects, even though the software can go online and see display statuses, indicating it knows the proper connections : A known "Data Server is not available"

+--------------------------------+ | FactoryTalk Directory Server | +--------------------------------+ | +------------------------+------------------------+ | | +------------------+ +------------------+ | HMI Server (A) | | HMI Server (B) | +------------------+ +------------------+ | | +------------------------+------------------------+ | +------------------------+------------------------+ | | | +------------------+ +------------------+ +------------------+ | Thin Client 1 | | Thin Client 2 | | Thick Client 3 | +------------------+ +------------------+ +------------------+

Intel Pentium 4, dual CPU, 3GHz or higher, 2GB RAM.

The software automatically surfaces extended tag metadata configured in ControlLogix or CompactLogix controllers. This includes engineering units, minimum/maximum limits, and custom descriptions, eliminating the need to recreate these definitions inside the HMI database.

: If upgrading by a different administrator, ensure InfluxDB permissions are maintained. Either transfer the .influxdbv2 folder to the new administrator's profile or grant necessary permissions before upgrading